Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS
Choose a sub category:
CIRCUIT BREAKERS - SNGL POLE CIRCUIT BREAKERS - DBL POLE CIRCUIT BREAKERS - ARC FAULT
CIRCUIT BREAKERS - GFCI FUSES-CARTRIDGE/LINKS/ADAPTER FUSES-PLUG/ADAPTERS
FUSES-SPECIALTY
Sort By:
Page of 2
FUSE GLS P RATED 25A 125V 1/PK FUSE GLS P RATED 15A 125V 1/PK FUSE GLS P RATED 30A 125V 1/PK
Leviton Plug Fuse, Type P, 25 A, 125 V, Round Glass Body Leviton Plug Fuse, Type P, 15 A, 125 V, Round Glass Body Leviton Plug Fuse, Type P, 30 A, 125 V, Round Glass Body
PLG FUSE TM DLY 20A 125V      PLG FUSE TM DLY 25A 125V      PLG FUSE TM DLY 15A 125V
Leviton Plug Fuse, Time Delay, Type D, 20 A, 125 V, Round Glass Body Leviton Plug Fuse, Time Delay, Type D, 25 A, 125 V, Round Glass Body Leviton Plug Fuse, Time Delay, Type D, 15 A, 125 V, Round Glass Body
Bussmann P-20 One Time Plug Fuse Bussmann P-30 One Time Plug Fuse Bussmann P-25 One Time Plug Fuse
Bussmann Plug Fuse, One Time, Series: P, 20 A, 125 VAC, Dual Element, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection Bussmann Plug Fuse, One Time, Series: P, 30 A, 125 VAC, Dual Element, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection Bussmann Plug Fuse, One Time, Series: P, 25 A, 125 VAC, Dual Element, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection
FUS CRTG 30A 250V 1/PK        Bussmann MAS-3X5 Electronic Fast Acting Fuse with Clip Strips FUS CRTG 15A 250V 1/PK
Leviton Fuse Cartridge, Type P, 30 A, 250 V, Cylinder Shaped Body Fast-acting 3 amp fuses. Leviton Fuse Cartridge, Type P, 15 A, 250 V, Cylinder Shaped Body
FUS CRTG 40A 250V 1/PK        FUS CRTG 60A 250V 1/PK        Bussmann Fusetron TC-20 Time Delay Plug Fuse
Leviton Fuse Cartridge, Type P, 40 A, 250 V, Cylinder Shaped Body Leviton Fuse Cartridge, 60 A, 250 V, Cylinder Shaped Body Bussmann Fusetron Plug Fuse, Time Delay, Series: TC, 20 A, 125 VAC, 4 hr at 110%, 60 min at 135%, 5 sec at 200% Response, Dual Element, 1.16 in Diameter, 1-1/4 in Length, CSA Certified, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection
Bussmann Fusetron TC-30 Time Delay Plug Fuse Bussmann Fusetron TC-25 Time Delay Plug Fuse Bussmann Fusetron TC-15 Time Delay Plug Fuse
Bussmann Fusetron Plug Fuse, Time Delay, Series: TC, 30 A, 125 VAC, 4 hr at 110%, 60 min at 135%, 5 sec at 200% Response, Dual Element, 1.16 in Diameter, 1-1/4 in Length, CSA Certified, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection Bussmann Fusetron Plug Fuse, Time Delay, Series: TC, 25 A, 125 VAC, 10 kA Interrupt, 4 hr at 110%, 60 min at 135%, 5 sec at 200% Response, Screw-In Body, Dual Element, Ceramic, 1.16 in Diameter, 1-1/4 in Length, CE Certified, CSA Certified, UL Listed, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection Bussmann Fusetron Plug Fuse, Time Delay, Series: TC, 15 A, 125 VAC, 4 hr at 110%, 60 min at 135%, 5 sec at 200% Response, Dual Element, 1.16 in Diameter, 1-1/4 in Length, CSA Certified, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection
Bussmann P-15 One Time Plug Fuse FUS CRTG 15A 600V 1/PK        FUS CRTG 50A 250V 1/BLK
Bussmann Plug Fuse, One Time, Series: P, 15 A, 125 VAC, Dual Element, Edison Base, For Residential and Industrial Branch Circuit and Motor Protection Mersen Fuse Cartridge, 15 A, 600 V, Cylinder Shaped Body Leviton Fuse Cartridge, Type P, 50 A, 250 V, Cylinder Shaped Body
Bussmann PON60 Cartridge One Time Low Voltage Time Delay Fuse FUSE CRTG 2IN 30A 250V        FUSE CRTG 2IN 20A 250V
Bussmann Time Delay Fuse, Cartridge, One Time, Low Voltage, Series: PON, 60 A, 250 VAC, 10 kA Interrupt, Ferrule, Non-Rejection Cylindrical Body, Dual Element, Fiberglass, 13/16 in Diameter, 3 in Length, CE Certified, CSA C22.2, For Protect of Motors and Branch Circuits Leviton Fuse Cartridge, Type D, 30 A, 250 V, Cylinder Shaped Body, 2 in Length Leviton Fuse Cartridge, Type D, 20 A, 250 V, Cylinder Shaped Body, 2 in Length
FUSE CRTG 2IN 15A 250V        Bussmann CDN30 Type D Cartridge Time Delay Fuse PLG FUSE TM DLY 15A 125V
Leviton Fuse Cartridge, Type D, 15 A, 250 V, Cylinder Shaped Body, 2 in Length Bussmann Time Delay Fuse, Type D, Cartridge, Series: CDN, 30 A, 250 VAC, 10 kA Interrupt, Blade Body, Dual Element, 9/16 in Diameter, 2 in Length, CSA Certified, For Protect of Motors and Branch Circuits Leviton Plug Fuse, Time Delay, Type D, 15 A, 125 V, Round Glass Body
PLG FUSE TM DLY 30A 125V      PLG FUSE TM DLY 20A 125V      MES Q115 Standard Miniature Circuit Breaker
Leviton Plug Fuse, Time Delay, Type D, 30 A, 125 V, Round Glass Body Leviton Plug Fuse, Time Delay, Type D, 20 A, 125 V, Round Glass Body MES Circuit Breaker, Standard, Miniature, 120/240 VAC, 15 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 1 Poles, Thermal Magnetic Actuator, 14 - 8 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Panelboard Mount
Eaton BR120 Type BR Miniature Circuit Breaker FUSE GLS P RATED 15A 125V 2/PK FUSE GLS P RATED 25A 125V 2/PK
Eaton Circuit Breaker, Type BR, Miniature, 120/240 VAC, 20 A, 1 Phase, 42 kA Interrupt, 1 Poles, Thermal Magnetic Actuator, 14 - 4 AWG Wire, Plug On Mounting, 2.92 in Overall Length, 0.98 in Overall Width, 2.89 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, 1 in Spacing Leviton Plug Fuse, Type P, 15 A, 125 V, Round Glass Body Leviton Plug Fuse, Type P, 25 A, 125 V, Round Glass Body
FUSE GLS P RATED 20A 125V 2/PK FUSE GLS P RATED 30A 125V 2/PK BR115 15A SINGLE POLE CIRCUIT
Leviton Plug Fuse, Type P, 20 A, 125 V, Round Glass Body Leviton Plug Fuse, Type P, 30 A, 125 V, Round Glass Body Eaton Circuit Breaker, Series: BR, 120/240 VAC, 15 A, 1, Thermal Magnetic Trip, 10 kA Interrupt, 1 Pole, 14 - 4 AWG Wire, Lug Terminal, 40 deg C, 1 in Overall Width, Standards: ANSI Certified, CSA Certified, UL Listed, Special Features: Plug-In Connection, Usage: Lighting Fixture Circuits
FUS CRTG 100A 250V 1/PK       Bussmann SL Time Delay Plug Fuse MES Q120 Standard Miniature Circuit Breaker
Mersen Fuse Cartridge, 100 A, 250 V, Cylinder Shaped Body Bussmann Plug Fuse, Time Delay, Bussmann, Series: SL, 25 A, 125 VAC, 10 kA Interrupt, Rejection Base Body, UL Listed, CE 248-11, For Small Motor and Inductive Load Circuits with High In-Rush Current Levels, Used with Box Cover Units Provide Equipment Protection MES Circuit Breaker, Standard, Miniature, 120/240 VAC, 20 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 1 Poles, Thermal Magnetic Actuator, 14 - 8 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Panelboard Mount
Homeline Square D CHOM120CP GFCI Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker Cooper Wiring NO.263 Fuse Reducer
Homeline Square D Circuit Breaker, GFCI, Series: CHOM, 120/240 VAC, 20 A, 1 Phase, 100A/HOM Frame, Fixed Trip, 27 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG Wire, Screw Clamp Terminal, Plug On Mounting, 3.13 in Overall Length, 1 in Overall Width, 2.98 in Overall Depth, CSA Certified, UL Listed, For Air Conditioning, Heating Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed. Cooper Wiring Fuse Reducer, 30 A Fuse, 60 A Fuse Block, 250 VAC, Class: H, K, CSA Certified, UL Listed
FUSE BRKR MINI 15A 125V       Square D QO115CP Type QO Standard Circuit Breaker GE THQL1140 Type THQL Q-Line Standard Circuit Breaker
Leviton Fuse Breaker, 15 A, 125 V Square D Circuit Breaker, Type QO, Standard, 120/240 VAC, 48 VDC, 15 A, 1 Phase, 100A Frame, Fixed Trip, 20.25 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG Wire, Pressure Plate/Screw Clamp Terminal, Plug On Mounting, 3 in Overall Length, 3/4 in Overall Width, 2.91 in Overall Depth, ANSI Specified, CSA Certified, UL Listed GE Circuit Breaker, Type THQL, Q-Line, Standard, 120/240 VAC, 40 A, 1 Phase, THQ Frame, Fixed Trip, 400 A Trip, 10 kA Interrupt, 1 Poles, 8 - 3 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1 in Spacing
GE THQL1150 Type THQL Q-Line Standard Circuit Breaker GE THQP140 Type THQP Q-Line Standard Circuit Breaker GE THQP115 Type THQP Q-Line Standard Circuit Breaker
GE Circuit Breaker, Type THQL, Q-Line, Standard, 120/240 VAC, 50 A, 1 Phase, THQ Frame, Fixed Trip, 500 A Trip, 10 kA Interrupt, 1 Poles, 8 - 3 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1 in Spacing GE Circuit Breaker, Type THQP, Q-Line, Standard, 120/240 VAC, 40 A, 1 Phase, Fixed Trip, 10 kA Interrupt, 1 Poles, Toggle Switch Actuator, 8 - 4 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1/2 in Overall Width, 2.58 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1/2 in Module GE Circuit Breaker, Type THQP, Q-Line, Standard, 120/240 VAC, 15 A, 1 Phase, Fixed Trip, 10 kA Interrupt, 1 Poles, Toggle Switch Actuator, 14 - 8 AWG/12 - 8 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1/2 in Overall Width, 2.58 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1/2 in Module
Bussmann Fusetron FRNR-30ID Cartridge Current Limiting Low Voltage Bussmann Fusetron FRNR-20ID Cartridge Current Limiting Low Voltage GE THQL1115 Type THQL Q-Line Standard Circuit Breaker
Bussmann Fusetron Time Delay Fuse, Heavy Duty, Cartridge, Current Limiting, Low Voltage, Series: FRN-R, 30 A, 250 VAC/125 VDC, 200 kA at 250 VAC, 20 kA at 125 VDC Interrupt, Class: RK5, 10 sec at 500% Response, Rejection Cylindrical Body, Dual Element, Fiberglass, 9/16 in Diameter, 2 in Length, Fuse Holder Code: H Bussmann Fusetron Time Delay Fuse, Heavy Duty, Cartridge, Current Limiting, Low Voltage, Series: FRN-R, 20 A, 250 VAC/125 VDC, 200 kA at 250 VAC, 20 kA at 125 VDC Interrupt, Class: RK5, 10 sec at 500% Response, Rejection Cylindrical Body, Dual Element, Fiberglass, 9/16 in Diameter, 2 in Length, Fuse Holder Code: H GE Circuit Breaker, Type THQL, Q-Line, Standard, 120/240 VAC, 15 A, 1 Phase, THQ Frame, Fixed Trip, 150 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG/12 - 8 AWG Wire, Screw Clamp Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed
GE THQP130 Type THQP Q-Line Standard Circuit Breaker GE THQP120 Type THQP Q-Line Standard Circuit Breaker MES Q220 Standard Miniature Circuit Breaker
GE Circuit Breaker, Type THQP, Q-Line, Standard, 120/240 VAC, 30 A, 1 Phase, Fixed Trip, 10 kA Interrupt, 1 Poles, Toggle Switch Actuator, 8 - 4 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1/2 in Overall Width, 2.58 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1/2 in Module GE Circuit Breaker, Type THQP, Q-Line, Standard, 120/240 VAC, 20 A, 1 Phase, Fixed Trip, 10 kA Interrupt, 1 Poles, Toggle Switch Actuator, 14 - 8 AWG/12 - 8 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1/2 in Overall Width, 2.58 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1/2 in Module MES Circuit Breaker, Standard, Miniature, 120/240 VAC, 20 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 2 Poles, 14 - 8 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, CSA Certified, UL Listed, Panelboard Mount, Used with Siemens Load Centers
MES Q230 Standard Miniature Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker Square D QO140CP Type QO Standard Circuit Breaker
MES Circuit Breaker, Standard, Miniature, 120/240 VAC, 30 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 14 - 6 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Panelboard Mount Homeline Square D Circuit Breaker, Standard, Series: CHOM, 120/240 VAC, 30 A, 1 Phase, 100A/HOM Frame, Fixed Trip, 40.5 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG Wire, Screw Clamp Terminal, Plug On Mounting, 3.13 in Overall Length, 1 in Overall Width, 2.98 in Overall Depth, CSA Certified, UL Listed, For Air Conditioning, Heating Square D Circuit Breaker, Standard, Type QO, 120/240 VAC, 48 VDC, 40 A, 1 Phase, 100A Frame, Fixed Trip, 54 A Trip, 10 kA Interrupt, 1 Poles, 12 - 2 AWG Wire, Box Lug Terminal, Plug-On Mounting, 3 in Overall Length, 3/4 in Overall Width, 2.91 in Overall Depth, Standards: CSA Certified, UL Listed, For QO Load Centers and NQOD Panelboards, Speed-D Switchboard Distribution Panels
Square D QO130CP Type QO Standard Circuit Breaker Federal Pioneer Stab-Lok NC Standard Circuit Breaker BR215 15A 2POLE CIRCUIT BREAKE
Square D Circuit Breaker, Type QO, Standard, 120/240 VAC, 48 VDC, 30 A, 1 Phase, 100A Frame, Fixed Trip, 40.5 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG Wire, Pressure Plate/Screw Clamp Terminal, Plug On Mounting, 3 in Overall Length, 3/4 in Overall Width, 2.91 in Overall Depth, ANSI Specified, CSA Certified, UL Listed Federal Pioneer Stab-Lok Circuit Breaker, Standard, Series: NC, 120 V, 15 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Actuator, 14 - 6 AWG Wire, Lug Terminal, Plug On Mounting, 40 deg C, White, For Lighting and Receptacle Circuits in a Home Eaton Circuit Breaker, Replacement, 120/240 VAC, 15 A, 2 Pole, CSA Certified, 1-UL Listed, Pliug-In Connection, For Internal and External Receptacles, Branch Circuit Protection, External Motors And Heating, Refrigeration Equipment and Air Conditioning
Federal Pioneer Stab-Lok NC Standard Circuit Breaker BRKR CIRC 2 POLE 15A 240V     GE THQL2140 Type THQL Q-Line Standard Circuit Breaker
Federal Pioneer Stab-Lok Circuit Breaker, Standard, Series: NC, 120 V, 20 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Actuator, 14 - 6 AWG Wire, Lug Terminal, Plug On Mounting, 40 deg C, White, For Lighting and Receptacle Circuits in a Home Siemens Circuit Breaker, Standard, Series: Q, 120/240 VAC, 15 A, 1, 125A/QP Frame, Fixed Instantaneous Trip, 15 Trip, 10 kA Interrupt, 2 Pole, 14 - 8 AWG Wire, Lug Terminal, 40 deg C, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, Standards: CSA Certified, UL Listed, Special Features: Plug-In Connection, Usage: Air Conditioning, Heating, Refrigeration and Distribution GE Circuit Breaker, Type THQL, Q-Line, Standard, 120/240 VAC, 40 A, 1 Phase, THQ Frame, Fixed Trip, 400 A Trip, 10 kA Interrupt, 2 Poles, 8 - 3 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, Panelboard Mount
GE THQP250 Type THQP Q-Line Thin Miniature Circuit Breaker BRKR CIRC 2 POLE 20A 240V     BRKR CIRC 30A BLK 120V
GE Circuit Breaker, Type THQP, Q-Line, Thin, Miniature, 120/240 VAC, 50 A, 1 Phase, Fixed Trip, 10 kA Interrupt, 2 Poles, Toggle Switch Actuator, 8 - 4 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.58 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed Siemens Circuit Breaker, Standard, Series: Q, 120/240 VAC, 20 A, 1, 125A/QP Frame, Common Trip, 20 Trip, 10 kA Interrupt, 2 Pole, 14 - 8 AWG Wire, Lug Terminal, 40 deg C, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, Standards: CSA Certified, UL Listed, Special Features: Plug-In Connection, Usage: Air Conditioning, Heating, Refrigeration and Distribution Siemens Circuit Breaker, Standard, Series: Q, 120 VAC, 30 A, 1, 125A/QP Frame, Fixed Instantaneous Trip, 30 Trip, 10 kA Interrupt, 1 Pole, 14 - 6 AWG Wire, Lug Terminal, 40 deg C, 2.88 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, Standards: CSA Certified, UL Listed, Special Features: Plug-In Connection, Usage: Air Conditioning, Heating, Refrigeration and Distribution
BRKR CIRC BLK 20A 2 SNGL POLES MES Q250 Standard Miniature Circuit Breaker BRKR CIRC BLK 15A 120V
Siemens Circuit Breaker, Duplex, 120 VAC, 20 A, 1, QT Frame, Fixed Instantaneous Trip, 10 kA Interrupt, 2 Pole, 14 - 8 AWG Wire, Lug Terminal, 40 deg C, 3-1/4 in Overall Length, 2 in Overall Width, 3 in Overall Depth, Standards: UL Listed, Special Features: Plug-In Connection, Usage: For Replacement Use only in Panels MES Circuit Breaker, Standard, Miniature, 120/240 VAC, 50 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 8 - 6 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Panelboard Mount Siemens Circuit Breaker, Duplex, 120 VAC, 15 A, 1, QT Frame, Fixed Instantaneous Trip, 10 kA Interrupt, 1 Pole, 14 - 8 AWG Wire, Lug Terminal, 40 deg C, 3-1/4 in Overall Length, 1 in Overall Width, 3 in Overall Depth, Standards: UL Listed, Special Features: Plug-In Connection, Usage: For Replacement Use only in Panels
Homeline Square D CHOM Standard Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker BQL20 20A SINGLE POLE CIRCUIT
Homeline Square D Circuit Breaker, Standard, Series: CHOM, 120/240 VAC, 20 A, 1 Phase, 100A/HOM Frame, Fixed Trip, 27 A Trip, 10 kA Interrupt, 2 Poles, 14 - 8 AWG Wire, Screw Clamp Terminal, Plug On Mounting, 3.13 in Overall Length, 2 in Overall Width, 2.98 in Overall Depth, CSA Certified, UL Listed Double pole 2" circuit breaker features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Eaton Circuit Breaker, Replacement, Series: Classic, BQL, 120/240 VAC, 20 A, 1, Thermal Magnetic Trip, 10 kA Interrupt, 1 Pole, 14 - 8 AWG Wire, Lug Terminal, 40 deg C, 2 in Overall Width, Standards: CSA Certified, UL Listed, Special Features: Bolt-On Connection, Usage: Internal and External Receptacles, Branch Circuit Protection, External Motors and Heating, Refrigeration Equipment and Air Conditioning
BQL15 15A SINGLE POLE CIRCUIT GE THQL1120 Type THQL Q-Line Standard Circuit Breaker GE THQL1130 Type THQL Q-Line Standard Circuit Breaker
Eaton Circuit Breaker, Replacement, Series: Classic, BQL, 120/240 VAC, 15 A, 1, Thermal Magnetic Trip, 10 kA Interrupt, 1 Pole, 14 - 8 AWG Wire, Lug Terminal, 40 deg C, 2 in Overall Width, 3-1/2 in Overall Depth, Plastic, Standards: CSA Certified, UL Listed, Special Features: Bolt-On Connection, Usage: Internal and External Receptacles, Branch Circuit Protection, External Motors and Heating, Refrigeration Equipment and Air Conditioning GE Circuit Breaker, Type THQL, Q-Line, Standard, 120/240 VAC, 20 A, 1 Phase, THQ Frame, Fixed Trip, 200 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG/12 - 8 AWG Wire, Screw Clamp Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed GE Circuit Breaker, Type THQL, Q-Line, Standard, 120/240 VAC, 30 A, 1 Phase, THQ Frame, Fixed Trip, 300 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG/12 - 8 AWG Wire, Screw Clamp Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed
BRKR CIRC 40A 30A USE NO8 WIRE Eaton BR220 Type BR Miniature Circuit Breaker Homeline Square D CHOMT Tandem Circuit Breaker
Schneider Circuit Breaker, Series: Stab-Lok, 40 A, Thermal Magnetic Trip, 1 Pole, 40 deg C Eaton Circuit Breaker, Type BR, Miniature, 120/240 VAC, 20 A, 1 Phase, 150A Frame, 42 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 14 - 4 AWG Wire, Plug On Mounting, 2.92 in Overall Length, 1.96 in Overall Width, 2.97 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For Overload and Short Circuit Protection of Home Electrical System Tandem 1" single-pole circuit breaker. Offers 2 circuits in the space of 1. Features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of the electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres.
Homeline Square D CHOMT Tandem Circuit Breaker BR230 30A 2POLE CIRCUIT BREAKE Square D QO220CP Type QO Standard Circuit Breaker
Tandem 1" single-pole circuit breaker. Offers 2 circuits in the space of 1. Features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of the electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Eaton Circuit Breaker, Series: BR, 120/240 VAC, 30 A, 1, Thermal Magnetic Trip, 10 kA Interrupt, 2 Pole, 14 - 4 AWG Wire, Lug Terminal, 40 deg C, 2 in Overall Width, Standards: ANSI Certified, CSA Certified, UL Listed, Special Features: Plug-In Connection, Usage: Oven and Clothes Dryer Circuits Square D Circuit Breaker, Type QO, Standard, 120/240 VAC, 20 A, 1 Phase, 100A Frame, Fixed Trip, 27 A Trip, 10 kA Interrupt, 2 Poles, 14 - 8 AWG Wire, Screw Clamp Terminal, Plug On Mounting, 3 in Overall Length, 1-1/2 in Overall Width, 2.91 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For QO Load Centers, CSEDs and NQOD Panel Boards
Square D QO215CP Type QO Standard Circuit Breaker GE THQP240 Type THQP Q-Line Standard Circuit Breaker GE THQP230 Type THQP Q-Line Standard Circuit Breaker
Square D Circuit Breaker, Type QO, Standard, 120/240 VAC, 15 A, 1 Phase, 100A Frame, Fixed Trip, 20.25 A Trip, 10 kA Interrupt, 2 Poles, 14 - 8 AWG Wire, Pressure Plate Terminal, Plug On Mounting, 3 in Overall Length, 0.2 in Overall Width, 2.91 in Overall Depth, ANSI Specified, CSA Certified, UL Listed GE Circuit Breaker, Type THQP, Q-Line, Standard, 120/240 VAC, 40 A, 1 Phase, Fixed Trip, 10 kA Interrupt, 2 Poles, Toggle Switch Actuator, 8 - 4 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.58 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1/2 in Module GE Circuit Breaker, Type THQP, Q-Line, Standard, 120/240 VAC, 30 A, 1 Phase, Fixed Trip, 10 kA Interrupt, 2 Poles, Toggle Switch Actuator, 8 - 4 AWG/8 - 2 AWG Wire, Lug Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 1 in Overall Width, 2.58 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed, 1/2 in Module
Eaton BR240 Type BR Miniature Circuit Breaker MES Q240 Standard Miniature Circuit Breaker BRKR CIRC 15A 240V BLK
Eaton Circuit Breaker, Type BR, Miniature, 120/240 VAC, 40 A, 1 Phase, 150A Frame, 42 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 14 - 4 AWG Wire, Plug On Mounting, 2.92 in Overall Length, 1.96 in Overall Width, 2.92 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For Overload and Short Circuit Protection of Home Electrical System MES Circuit Breaker, Standard, Miniature, 120/240 VAC, 40 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 8 - 6 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Panelboard Mount GE Circuit Breaker, Standard, Series: THQP, 120/240 VAC, 15 A, 1, Q-Line Frame, Non-Interchangeable Trip, 10 kA Interrupt, 2 Pole, 14 - 4 AWG Wire, Lug Terminal, 3.28 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, Standards: UL Listed, Special Features: Plug-In Connection, Usage: Residential, Reverse Feed
BRKR CIRC 2 POLE 30A 240V     GE THQL2120 Type THQL Q-Line Standard Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker
Siemens Circuit Breaker, Standard, Series: Q, 120/240 VAC, 30 A, 60 Hz, 1, 125A/QP Frame, Common Trip, 30 Trip, 10 kA Interrupt, 2 Pole, 14 - 6 AWG Wire, Lug Terminal, 40 deg C, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, Standards: CSA Certified, UL Listed, Special Features: Plug-In Connection, Usage: Air Conditioning, Heating, Refrigeration and Distribution GE Circuit Breaker, Type THQL, Q-Line, Standard, 120/240 VAC, 20 A, 1 Phase, THQ Frame, Fixed Trip, 200 A Trip, 10 kA Interrupt, 2 Poles, 14 - 8 AWG/12 - 8 AWG Wire, Screw Clamp Terminal, Plug In Mounting, 60 - 75 deg C, 3.28 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, Thermoset, ANSI Specified, CSA Certified, UL Listed Homeline Square D Circuit Breaker, Standard, Series: CHOM, 120/240 VAC, 30 A, 1 Phase, 100A/HOM Frame, Fixed Trip, 40.5 A Trip, 10 kA Interrupt, 2 Poles, 14 - 8 AWG Wire, Screw Clamp Terminal, Plug On Mounting, 3.13 in Overall Length, 2 in Overall Width, 2.98 in Overall Depth, CSA Certified, UL Listed